常规产品
热熔断体RV-1系列RV-2系列RV-3系列
产品简介:额定电流Rated Current:1A/2A/3A
额定电压Rated Voltage:250V/300V/320V AC
额定动作温度Tf:102C/115C/125℃/130℃/135℃/145℃/150℃/160℃
安全认证Safety Certification:cURus/CCC/TUV
一、额定动作温度(Tf)
在仅通以不超过10mA的探测电流的条件下测得的使热熔断体导电状态改变的温度,热熔断体必须在上述温度0/-10℃范围内动作。
Temperature of the thermal-link which causes it to change its state of conductivity with a detection current up to 10mA as the only load. Thermal fuse must be fusing within the scope of+ 0/-10℃.
二、熔断温度Fusing-off temperature
产品放置油槽内并通以不超过10mA电流值,然后以0.5K/min至1K/min的速率稳定升温,热熔断体实际动作温度值。
The fusing-off temperature indicates value measured in the test oil bath and temperature be increased steadily with a rate of rise between 0.5K/min to 1K/min and detective current 10mA or less.
三、保持温度(Th)
热熔断体在规定的条件下通过额定电流且保温168小时,其导电状态不发生改变的最高温度值或按IEC60691标准测试值。
The maximum temperature at